🔗 SMALL SIROCCO FAN (MOTOR DIRECT)

Characteristics

Low sound levels.

Easy installation.

Easy to check and repair by removing the motor and the fan.

The appearance of quadrilateral improved efficiency of installation at the desired location.

Allowable temperature range: -10℃~+50℃ (It is even operable up to 90% of relative humidity under the room temperature.

Usages

Ventilation, Blowing and air conditioning in every building apartment, underground market, factory, house, office, warehouse, etc.

Fans for assembly in apparatus and coolers: commutators, transformers, dryers, etc.

Specifications

MODELImpeller (mm)Poles (P)PowerAir Volume (㎥/h)Static Pressure (mmAq)Current (A)Input(W)Weight(Kg)
TFB-F16BS16041Ø 220V 50Hz770140.61215.6
TFB-F19DS18041Ø 220V 50Hz1400211.325011
TFB-F19DT18043Ø 220V380V 50Hz1450211.5/0.927011
TFB-G25DS25061Ø 220V 50Hz2000161.735020
TFB-G25DT25063Ø 220V380V 50Hz2000172.0/1.233020
TFB-F28FS25041Ø 220V 50Hz3300404.997524
TFB-F28FT25043Ø 220V380V 50Hz3350346.4/3.7120023
TFB-G29ES25061Ø 220V 50Hz2600212.540622
TFB-G29ET25063Ø 220V380V 50Hz2400192.1/1.237022
TFB-F29FS25041Ø 220V 50Hz4050406.2120025
TFB-F29FT25043Ø 220V380V 50Hz3800434.7/2.7105025
TFB-F30FS25041Ø 220V 50Hz5300597.6127528
TFB-F30FT25043Ø 220V380V 50Hz5300594.7/2.7110028
TFB-F33HS33041Ø 220V 50Hz792010111.2245042
TFB-F33HT33043Ø 220V380V 50Hz79201019.7/5.6300041
TFB-G39HT39063Ø 220V380V 50Hz96005512.6/7.3251070

 Dimensions

ModelABCDEFGDuct
HIJKNP
TFB-16BS24118713360301503521.51701502551010Ø150
TFB-19**30024017085301993021.51851652741610Ø200
TFB-G25**3803002151053524950242252053412012Ø250
TFB-F28**395320223934724751.6242502303412012Ø250
TFB-G29**395320223934729851.6242502303412012Ø300
TFB-F29**395320223934729851.6242502303412012Ø300
TFB-F30**39532022398.668.329750242902703932012Ø300

 

TFB-F33HS/HT

 

TFB-G39HT

 

Amount of Ventilation 

Ventilation Amount per Hour
Ventilation Amount : Space Volume X Number of Ventilation Required per Hour
Ex) 10m wide x 10m long x 3m high (10x10x3=300), kitchen (15): 300x15 = 4,500 minimum ventilation required
banquet hall8Factorygeneral factory5~15
dinning hall8machine factory10~20
Hotel,cuisine15welding factory15~25
Accomodationcorridor5casting factory20~60
toilet10casting, rolling mill30~80
engine boiler room20chemical plant15~30
laundry room15food factory10~30
Hospitalwaiting room10coating factory30~100
treatment room6printing factory5~15
sickroom6woodworking factory15~25
bathroom10dyeing factory15~30
office6spinning mill5~15
restaurant8substation room20~30
cuisine15compressor room15~30
corridor5Supplementaryboiler room20~30
toilet10Equipmentslecture hall4~15
engine boiler room10restaurant5~10
laundry room15kitchen10~30
operating room15Theaterviewing room6
disinfection room12projection room20
respiratory ward room10Restaurantrestaurant6
Public Toiletpublic toilet20cuisine20
Parlorparlor6fried food restaurant20
Libraryreading room6banquet room10
Schoolgym5~10Generaloffice3~10
lecture hall6~10meeting room5~12
kitchen 5~15
living room2~5